Published 2024-12-01
license
Research Article (before OJS)

Validation of the analytical method by HPLC for the quantification of trace amounts of the drug Meloxicam in equipment and manufacturing areas

DOI: https://doi.org/10.22490/24629448.10563
Kelly Johana Rojas Universidad del Valle
Natalia Afanasjeva Universidad del Valle

Introduction. In the pharmaceutical industry, the quantification of trace amounts of active ingredients in drugs is essential to validate post-manufacturing cleaning processes, given the risk of cross-contamination resulting from inadequate cleaning process. Objective. To validate an analytical methodology in tropical climate conditions to quantify traces of the non-steroidal anti-inflammatory drug (NSAID) or Meloxicam in manufacturing equipment using high performance liquid chromatography (HPLC). Methodology. The analysis was carried out on Zorbax Eclipse XDB-C18 column (4.6 x 150 mm, 5 µm, Agilent) at 30°C ± 2°C.  The mobile phase consisted of 90% monobasic ammonium phosphate buffer (pH 7.0) with 2-propanol and methanol, and 10% methanol, at a flow rate of 1.0 mL/min. Detection was performed at 360 nm, with an injection volume of 10 µL, and the same mobile phase was used as diluent. Results. The method showed excellent linearity, with a statistical correlation coefficient R ≥ 0.999. The coefficient of variation did not exceed the RSD limit of 13% in the repeatability of the system in all the surfaces evaluated and in intermediate precision the criterion of RSD < 20.0% was fulfilled. Accuracy test yielded a recovery percentage above the acceptance criterion of 50%. There were no interferences in the specificity. Conclusions. The studies performed validate the proposed HPLC methodology for the quantification of Meloxicam traces by HPLC, showing that is precise, accurate, selective, efficient, robust and suitable to carry out in pharmaceutical analysis laboratories. Moreover, the optimization of critical parameters un tropical climate conditions, such as filter type, time and nature of the extraction solvent, as well as the stability of the method, also provided a solid basis for its implementation in the quality control area.

keywords: High performance liquid chromatography, non-steroidal anti-inflammatory drugs, trace, analytical method validation, statistics and numerical data., high performance liquid chromatography, non-steroidal anti-inflamatory drugs, analytical method validation, statics and numerical data
license

How to Cite

Rojas, K. J., & Afanasjeva, N. (2024). Validation of the analytical method by HPLC for the quantification of trace amounts of the drug Meloxicam in equipment and manufacturing areas. NOVA Biomedical Sciences Journal, 24(46), 95-116. https://doi.org/10.22490/24629448.10563
Almétricas
Metrics
Metrics Loading ...

PRIVACY STATEMENT: In accordance with the Personal Data Protection Law (Law 1581 of 2012), the names and email addresses managed by Revista NOVA will be used exclusively for the purposes stated by this journal and will not be made available for any other purpose or to any other individual. Manuscripts submitted to the publication are only accessible to the editorial team and external peer reviewers.

Design and implemented by