Importance of the dilution test in the dosage of coagulation factors XII and XI in plasma with positive lupus anticoagulant

DOI: https://doi.org/10.22490/24629448.7539
Martha Castillo Universidad Colegio Mayor de Cundinamarca
Ana Isabel Mora Bautista Universidad Colegio Mayor de Cundinamarca
Ana lucía Oliveros Universidad Colegio Mayor de Cundinamarca
Gloria Ramos Universidad Militar Nueva Granada
Maria Elena Muñoz Zambrano Universidad Nacional Mayor de San Marcos
Jonathan Andre Mora Fundación Santa Fe de Bogotá

Introduction. Thrombosis is associated with acquired risk factors or hypercoagulable states. Antiphospholipid antibodies are found in infectious processes or associated with arterial or venous thrombosis. Among these is the lupus anticoagulant, which is conside- red an interference inhibitor because it prolongs phospholipid-dependent tests in vitro. Objectives. To relate the activity of factor XII and XI in patients with positive lupus anti- coagulant. Methodology. Of 55 plasmas, 34 met the inclusion criteria. Factors XII and XI were dosed by metric clot methods. Samples less than 50 Ul/dl are considered low factor activity, to which the dilution test (parallelism) is performed. If a recovery greater than 15% of the factor is evidenced, it is considered interference. If, on the contrary, the result remains with little variation, it is confirmed. factor deficiency. Results. Of 34 dosages, 79.4% (27/34) presented a decrease in factor XI. A dilution test was performed, and 100% recovery of factor XI was observed; Regarding the dosage of factor XII, 29.4% (10/34) presented values below 50 IU/dl and 70.6% (24/34) normal, did not recover in 22.2% (2/9) presenting deficit. Conclusions. The study of a prolonged PTT is carried out due to suspicion of lupus anticoagulant or factor deficiency. The importance of the laboratory is that every time a decreased coagulation factor is found, plasma dilution must be done to determine if there is recovery of the factor or is a deficit of this.

Palabras clave: Antiphospholipid syndrome, Dilution, Factor XII, Factor X, Anticoagulant , Lupus
Licencia

Derechos de autor 2023 Nova

Creative Commons License

Esta obra está bajo una licencia internacional Creative Commons Atribución-NoComercial-SinDerivadas 4.0.

Cómo citar
Castillo , M. ., Mora Bautista, A. I., Oliveros , A. lucía, Ramos , G., Muñoz Zambrano , M. E. ., & Mora, J. A. . (2023). Importance of the dilution test in the dosage of coagulation factors XII and XI in plasma with positive lupus anticoagulant. Revista Nova publicación científica En Ciencias biomédicas, 21(41). https://doi.org/10.22490/24629448.7539
Almétricas
Social Media
  • Shares, Likes & Comments: 1
Métricas
Archivos descargados
75
Dec 16 '23Dec 19 '23Dec 22 '23Dec 25 '23Dec 28 '23Dec 31 '23Jan 01 '24Jan 04 '24Jan 07 '24Jan 10 '24Jan 13 '243.0
|

DECLARACIÓN DE PRIVACIDAD: Según la Ley de Protección de Datos Personales (Ley 1581 de 2012), los nombres y direcciones de correo electrónico manejados por Revista NOVA se usarán exclusivamente para los fines declarados por esta revista y no estarán disponibles para ningún otro propósito u otra persona. Los manuscritos enviados a la publicación solo son conocidos por el equipo editorial y por los pares evaluadores externos.

Diseño e implementado por